Section 2: introduction, 01 scope of manual, 02 power supply specifications – Tweco 151 CutMaster User Manual

Page 13: Section 2, Introduction -1

Advertising
background image

Manual 0-4668

2-1

INTRODUCTION

SECTION 2:

INTRODUCTION

2.01 Scope of Manual

This manual contains descriptions, operating instructions and basic maintenance procedures for the Thermal Dynamics®
CutMaster™ 151 Plasma Cutting Power Supply only. Servicing of this equipment is restricted to properly trained personnel;
unqualified personnel are strictly cautioned against attempting repairs or adjustments not covered in this manual, at the risk of
voiding the Warranty.

Read this manual thoroughly. A complete understanding of the characteristics and capabilities of this equipment will assure the
dependable operation for which it was designed.

NOTE

Refer to the Torch Manual for torch and cutting information.

2.02 Power Supply Specifications

Output Current
Power Supply
Gas Filtering Ability

Ambient Temperature

IEC

Rating

TDC

Rating

IEC

Rating

TDC

Rating

IEC

Rating

TDC

Rating

Duty Cycle
Current

100A

- 73A

- 50A

-

DC

Voltage

120V

- 110V

- 100V

-

CutMaster™ 151 Power Supply Specifications

208 / 230 VAC (187 - 253 VAC), Single Phase, 50/60 Hz

460 VAC (414 - 506 VAC), Single Phase, 50/60 Hz

400 VAC (360-440 VAC), Single Phase, 50/60 Hz

25 - 100 Amps, Continuously Adjustable

400 VAC (360-440 VAC), Three Phase, 50/60 Hz

600 VAC (517 - 632 VAC), Three Phase, 60 Hz

Input Power

460 VAC (414 - 506 VAC), Three Phase, 50/60 Hz

* NOTE: The duty cycle will be reduced if the primary input power (AC) is low

or the output voltage (DC) is higher than shown in this chart.

Particulates to 20 Microns

CutMaster™ 151 Power Supply Duty Cycle *

40° C (104° F)

40%

60%

100%

NOTE:

IEC Rating is determined as specified by the International Electro-Technical Commission. These specifications
include calculating an output voltage based upon power supply rated current. To facilitate comparison between
power supplies, all manufacturers use this output voltage to determine duty cycle.

TDC Rating is determined using an output voltage representative of actual output voltage during cutting with a TDC
torch. This voltage may be more or less than IEC voltage, depending upon choice of torch, consumables, and actual
cutting operation.