02 preparations for operating, 02 preparations for operating -2 – Tweco 151 CutMaster User Manual

Page 26

Advertising
background image

OPERATION

4-2

Manual 0-4668

4.02 Preparations For Operating

Perform the following steps at the start of each operating session:

WARNING

Disconnect primary power at the source before assembling or disassembling power supply, torch parts, or torch and
leads assemblies.

A. Torch Parts Selection

Check the torch for proper assembly and appropriate torch parts. The torch parts must correspond with the type of
operation, and with the amperage output of this Power Supply (100 amps maximum). Refer to the Torch Manual.

B. Torch Connection

Check that the torch is properly connected. Only Thermal Dynamics model SL60™ or SL100™ Torches may be
connected to this Power Supply.

WARNING

If an SL60 Torch is used on this unit, do not exceed an output setting (dial on front of unit) higher than 60.

C. Check Primary Input Power Source

1.

Check the power source for proper input voltage. Make sure the input power source meets the power require-
ments for the unit per Section 2, Specifications.

2.

Connect the input power cable (or close the main disconnect switch) to supply power to the system.

D. Gas Selection

Ensure compressed air source meets requirements (refer to

Section 3.4). Check connections and turn gas supply

on.

E. Connect Work Cable

Clamp the work cable to the workpiece or cutting table. The area must be free from oil, paint and rust. Connect
only to the main part of the workpiece; do not connect to the part to be cut off.

Art # A-04509

Advertising