INSTALLATION 3-2 Manual 0-5178

3.03 Primary Input Power Connections

Power Cord and Plug
This power supply comes installed with a input power cable with no plug, single-phase input power.

CAUTION

Check your power source for correct voltage before plugging in or connecting the unit. The primary power

source, fuse, and any extension cords used must conform to local electrical code and the recommended

circuit protection and wiring requirements as specified in Section 2.

Input Voltage (VAC)

Rated Output

Amps (RMS) input at rated
output, 60 Hz, single-phase

kVA

115V, 16A Circuit

20A, 88V

21.3

2.5

115V, 32A Circuit

27A, 91V

21.3

3.5

230V, 16A Circuit

40A, 96V

23-21.4

4.8

3.04 Air Supply Connections

A. Connecting Air Supply to Unit
The connection is the same for compressed air or industrial compressed air in gas cylinders.
1. Connect the gas line to the compressed air inlet port at the appropriate pressure.

Art# A-09337

Air Inlet

On/Off

Switch

Figure 3-2 Gas Connection to Compressed Air input