OPERATION 4-2 Manual 0-5178

6.

READY (DC Indicator)

Indicator is ON when DC output circuit is active.

NOTE

All consumables must be correctly installed and maintained to ensure correct operation.

4.02 Preparations For Operating

At the start of each operating session:

WARNING

Disconnect primary power at the source before assembling or disassembling power supply, torch parts,

or torch and leads assemblies.

A. Torch Parts Selection

Check the torch for proper assembly and appropriate torch parts. The torch parts must correspond with the type

of operation, and with the amperage output of this power supply (40 amps maximum). Use only genuine Thermal

Dynamics parts with this torch.

Art # A-09411

Large O-Ring,

Cat. No. 8-3487

Small O-Ring,

Cat. No. 8-3486

Electrode, Cat. No. 9-8215

Start Cartridge,
Cat. No. 9-8213

Worn Electrode

Worn Tip

40 Amp Drag Tip, Cat. No. 9-8207

Shield Cup, Cat. No. 9-8218

NOTE

When operating the torch in a normal condition, some gas vents through the gap between the shield cup

and torch handle. Do not attempt to over tighten the shield cup as irreparable damage to internal compo-

nents may result.