Tweco A80-A120 CutMaster User Manual

Page 24

Advertising
background image

CUTMASTER A80, A120

INSTALLATION Manual 0-5119

3-2

NOTE

The upper screws and lower screws are not the

same. Do not mix them. The upper screws are

for threading into the plastic of the front and rear

panels. DO NOT use the finer threaded lower

screws for this.

Art # A-08429

Lower

Screws

Lower

Screws

Slots

Upper

Screws

2. Carefully pull the Cover up and away from the

unit.

B. Cover Installation

1. Reverse previous procedures for cover instal-

lation.

NOTE

When installing the upper screws, attempt to

reuse the original threads. The easiest way to

do this is by turning the screw counter-clockwise

until you feel the threads line up, then begin to

turn the screw clockwise to tighten. Do not

over tighten.

C Primary Input Power Connections

CAUTION

Check your power source for correct voltage

before plugging in or connecting the unit. The

primary power source, fuse, and any extension

cords used must conform to local electrical code

and the recommended circuit protection and

wiring requirements as specified in Section 2.

The following illustration and directions are for wiring
three phase input power.

Art # A-08548

Input Power Cable Connections

Three-Phase (3ø)

GND

L1

L2

L3
L4

Three Phase Input Power Wiring

D. Connections to Three Phase Input Power

WARNING

Disconnect input power from the power supply

and input cable before attempting this procedure.

These instructions are for changing the input power

and or cable on the 208/230, 400, 460 VAC Power Sup-

ply to Three - Phase input power.

1. Remove the Power Supply cover per instruc-

tions found in this subsection A.

2. Disconnect the original input power cable

from the main input contactor and the chassis

ground connection.

3. Loosen the through - hole protector on the back

panel of the power supply. Pull the original

power cable out of the power supply.

4. Using a customer supplied four - conductor

input power cable for the voltage desired, strip

back the insulation on the individual wires.

5. Pass the cable being used through the access

opening in the back panel of the power supply.

Refer to Section 2 for power cable specifica-

tions.

CAUTION

The primary power source and power cable must

conform to local electrical code and the recom-

mended circuit protection and wiring require-

ments (refer to table in Section 2).

6. Connect the wires as follows.

• Wires to L1, L2 and L3 input. It does not

matter what order these wires are attached.

See previous illustration and on label in the

power supply.

• Green / Yellow wire to Ground.

Advertising