INSTALLATION PROCEDURES

3-2

Manual 0-2479

3.05 Mounting Bracket Assembly

Installation

The Mounting Bracket Assembly is used to mount the
Standoff Control Assembly and must be installed in a suit-
able location where it is easily accessable to the system
operator. The unit can be mounted on top of or under-
neath a mounting surface.

Install the Mounting Bracket Assembly per the following
procedure:

1. Select the mounting surface for the Mounting

Bracket.

2. Mount the bracket to the surface either on top of

or underneath the surface using four 1/4" bolts
(not supplied). It is recommended to use at least
four bolts to mount the bracket but a minimum
of two are required.

NOTE

There are seven holes provided in the Mounting
Bracket. Use any four holes that are convenient
for the application.

1/4" Mounting Bolts

(Not Supplied)

Mounting Holes

(Seven Places)

A-00671

Figure 3-1 Bracket Mounting On Top Of Surface

A-00672

1/4" Mounting Bolts

(Not Supplied)

Mounting Holes

(Seven Places)

Figure 3-2 Bracket Mounting Underneath Surface

3.06 Standoff Control Assembly

Installation

The Standoff Control and Remote Control must be in-
stalled together and interconnected with an internal rib-
bon jumper cable. The enclosures for both units are de-
signed to be placed one on top of the other and secured
together with four #6-32x1/2 inch thread forming screws,
two in front panel and two in rear panel. It makes no
difference which unit goes on top as the installation is
the same.

Install the Remote Control and Standoff Control Assem-
blies per the following procedure:

1. Install the Mounting Bracket per Section 3.05.

2. Decide which unit will be the top unit, the Re-

mote Control or the Standoff Control.

3. On the top unit remove the two cover mounting

screws on the top of the unit.

Advertising