Tweco 200 Ultra-Cut User Manual

Page 116

Advertising
background image

TORCH INFORMATION

7-4

Manual 0-5056 Ultra-Cut 200

2, Remove the Removal Tool from the Cartridge and install the assembled Cartridge onto the Torch Head.

The cartridge assembly must cover the O-Ring on the torch head.

Do not force the cartridge if it will not tighten fully. Remove the cartridge assembly and gently clean the threads on
the torch head with a wire brush. Apply oxygen-compatible lubricant (supplied with the torch) to the threads.

Torch Head O-Ring

Torch Head

Art # A-08300_AB

0.063 - 0.083"
(1.6 - 2.1 mm)

Protrusion

Installing Assembled Cartridge Onto Torch Head

3. Slide the ohmic clip over the shield cup if using ohmic torch height control sensing.

Ohmic Clip

Art # A-03393_AB

4. Connect the wire lead from the height finder to the ohmic clip.

Ohmic height sensing is not recommended with water shield. Water on the plate interferes electrically with the ohmic
sensing circuit.

Advertising