Manual No. 0-5056 Ultra-Cut 200

3-9

INSTALLATION

2. Grounding for components mounted on the cutting table (CNC controllers, height controllers, plasma remote

controls, etc.) should follow the manufacturer’s recommendations for wire size, type, and connection point
locations.

For Thermal Dynamics components (except Remote Arc Starter and Gas Control Module) it is recommended
to use a minimum of 10 AWG (European 6 mm

2

) wire or flat copper braid with cross section equal to or greater

than 10 AWG connected to the cutting table frame. The Remote Arc Starter uses 1/0 earth ground wire and the
Gas Control Module should use minimum # 4 AWG wire. The connection point must be to clean bare metal; rust
and paint make poor connections. For all components, wires larger than the recommended minimum can be
used and may improve noise protection.

3. The cutting machine frame is then connected to the “Star” point using 1/0 AWG (European 50 mm

2

) or larger

wire.

4. The plasma power supply work cable (see NOTE) is connected to the cutting table at the single point “Star” ground.

NOTE

Do Not connect the work cable directly to the ground rod.

5. Make sure work cable and ground cables are properly connected. The work cable must have a solid connection

to the cutting table. The work and ground connections must be free from rust, dirt, grease, oil and paint. If
necessary grind or sand down to bare metal. Use lock washers to keep the connections tight. Using electrical
joint compound to prevent corrosion is also recommended.

6. The plasma power supply chassis is connected to the power distribution system ground as required by electri-

cal codes. If the plasma supply is close to the cutting table (see NOTE) a second ground rod is not usually
needed, in fact it could be detrimental as it can set up ground loop currents that cause interference.

When the plasma power supply is far away from the ground rod and interference is experienced, it may help to
install a second earth ground rod next to the plasma power supply. The plasma power supply chassis would
then be connected to this ground rod.

NOTE

It is recommended that the Plasma Power Supply be within 20 - 30 ft (6.1 – 9.1 m) of the cutting table,
if possible.

7. The plasma control cable should be shielded with the shield connected only at the cutting machine end.

Connecting the shield at both ends will allow ground loop currents which may cause more interference than with
no shield at all.