CUTMASTER 152

INSTALLATION

Manual 0-4987

3-2

B. Connections to Three Phase Input Power

WARNING

Disconnect input power from the power

supply and input cable before attempting

this procedure.

These instructions are for changing the input power and

or cable on the 208/230, 400, 460 VAC Power Supply to

Three - Phase input power.

1. Remove the Power Supply cover per instructions

found in section 5.

2. Disconnect the original input power cable from

the main input contactor and the chassis ground
connection.

3. Loosen the through - hole protector on the back

panel of the power supply. Pull the original
power cable out of the power supply.

4. Using a customer supplied four - conductor input

power cable for the voltage desired, strip back
the insulation on the individual wires.

5. Pass the cable being used through the access

opening in the back panel of the power supply.
Refer to Section 2 for power cable specifications.

CAUTION

The primary power source and power cable

must conform to local electrical code and the

recommended circuit protection and wiring

requirements (refer to table in Section 2).

6. Connect the wires as follows.

• Wires to L1, L2 and L3 input. It does not

matter what order these wires are attached.

See previous illustration and on label in the

power supply.

• Green / Yellow wire to Ground.

7. With a little slack in the wires, tighten the through

- hole protector to secure the power cable.

8. Reinstall the Power Supply cover per instructions

found in section 5.

9. Connect the opposite end of individual wires to

a customer supplied plug or main disconnect.

10. Connect the input power cable (or close the main

disconnect switch) to supply power.

These instructions are for changing the input power and

or cable on the 208/230, 400, 460 VAC Power Supply to

Single - Phase input power.

1. Remove the Power Supply cover per instructions

found in section 5.

2. Disconnect the original input power cable from

the main input contactor and the chassis ground
connection.

3. Loosen the through - hole protector on the back

panel of the power supply. Pull the original
power cable out of the power supply.

4. If the power cable being used is not the factory

- supplied cable, use a three - conductor input
power cable for the voltage desired and strip
back the insulation on the individual wires.

5. Pass the cable being used through the access

opening in the back panel of the power supply.
Refer to Section 2 for power cable specifications.

CAUTION

The primary power source and power cable

must conform to local electrical code and the

recommended circuit protection and wiring

requirements (refer to table in Section 2).

6. Connect the wires as follows.

• Connect Bus Bar Jumpers on the contactor as

shown in prior illustration and on label in the

power supply.

• Green / Yellow wire to Ground.

8. Reinstall the Power Supply cover per instructions

found in section 5.

9. Connect the opposite end of individual wires to

a customer supplied plug or main disconnect.

10. Connect the input power cable (or close the main

disconnect switch) to supply power.