Cutmaster 152 – Tweco 152 CutMaster User Manual

Page 26

Advertising
background image

CUTMASTER 152

INSTALLATION

Manual 0-4987

3-4

Regulator

Input

Gas Supply

Hose

1/4 NPT to 1/4”

(6mm) Fitting

Regulator/Filter

Assembly

2-Stage Filter

Inlet Port (IN)

Outlet Port

(OUT)

Two Stage

Filter

Assembly

Art # A-07945_AC

Hose Clamp

Optional Two - Stage Filter Installation

Using High Pressure Air Cylinders

When using high pressure air cylinders as the air supply:

1. Refer to the manufacturer’s specifications for

installation and maintenance procedures for high

pressure regulators.

2. Examine the cylinder valves to be sure they are

clean and free of oil, grease or any foreign mate-

rial. Briefly open each cylinder valve to blow out

any dust which may be present.

3. The cylinder must be equipped with an adjust-

able high - pressure regulator capable of outlet

pressures up to 100 psi (6.9 bar) maximum and

flows of at least 300 scfh (141.5 lpm).

4. Connect supply hose to the cylinder.

NOTE

Pressure should be set at 100 psi (6.9 bar) at

the high pressure cylinder regulator.
Supply hose must be at least 1/4 inch (6

mm) I.D.
For a secure seal, apply thread sealant to the

fitting threads, according to manufacturer's

instructions. Do Not use Teflon tape as a

thread sealer, as small particles of the tape

may break off and block the small air pas-

sages in the torch.