Cutmaster 40mm, 04 fault indicator – Tweco 40mm Cutmaster User Manual
Page 57
CUTMASTER 40mm
Manual 0-5084
5-3
SERVICE
5.04 Fault Indicator
At initial power up, two lights will temporarily
illuminate for 2-3 seconds to show the version of
software used.
To determine the first digit, count the function
indicators left to right, 1 through 5. To determine
the second digit count the pressure indicators,
reading from bottom to top, 0 through 7. In the
example below the Temp indicator and 75 psi
indicators are on indicating the version would be
2.3.
A
+
PSI
BAR
MAX
MAX
MIN
MIN
!
1 2 3 4
Art# A-07988
MIN
MAX
0
1
2
3
4
5
6
7
5
When the
!
"Fault" indicator is ON or blinking
it will be accompanied by one of the pressure in-
dicator lights depending on what the Fault is. The
following table explains each of those Faults.
Pressure
Indicator
Fault
Max
Over Pressure
90
Internal Error
85
Shorted Torch
80
Consumables Missing
75
Start Error
70
Parts in Place
65
Input Power
Min
Under Pressure
NOTE
Fault explanations are covered in the following
tables.