Input Mains Voltage (50/60 Hz)
V 208 230 400 460 208 230 400 460 208 230 400 460
Mains Voltage Tolerance Range
%
Max Recommended Circuit Breaker or Time-Delay Fuse
3 Phase
A
-
-
-
-
45
40
25
20
70
60
35
30
Max Recommended Standard Normal Operating Fuse
3 Phase
A
-
-
-
-
55
50
30
25
80
70
40
35
Max Recommended Circuit Breaker or Time-Delay Fuse
1 Phase
A
70
60
40
35
100 90
50
45 100 90
50
45
Max Recommended Standard Normal Operating Fuse
1 Phase
A
80
70
45
40
110 100 60
50 110 100 60
50
Power factor at Maximum Output
cos
Maximum Open Circuit Voltage
OCV
V
Voltage Range for GMAW-P, GMAW, FCAW, MIG
U 2min-U 2max
V
Current Range for GMAW-P, GMAW, FCAW, MIG
I 2min-I 2max
A
Current Range for SMAW (Stick)
I 2min-I 2max
A
Enclosure Protection Class to EN 60 529
Insulation Class
Cooling Method
Noise Emission
dB (A)
Welding Output
Duty Cycle 100%
3 Phase
A
Duty Cycle 60%
3 Phase
A
Duty Cycle at Maximum Current
3 Phase
X
Input Mains Voltage (50/60 Hz)
3 Phase
V
-
-
-
-
208 230 400 460 208 230 400 460
Input Power S1 at 100% Duty Cycle
3 Phase
kVA
-
-
-
-
11
11
12
12
16
16
16
17
Input Power S1 at 60% Duty Cycle
3 Phase
kVA -
-
-
-
13
13
14
14
24
23
23
24
Input Power S1 at Maximum Current
3 Phase
kVA -
-
-
-
17
16
17
17
24
23
23
24
Generator Requirement with Three Phase
3 Phase
kVA
Input Current I1 at 100% Duty Cycle
3 Phase
A
-
-
-
-
32
29
18
16
45
40
23
21
Input Current I1 at 60% Duty Cycle
3 Phase
A
-
-
-
-
37
33
20
17
66
59
34
30
Input Current I1 at Maximum Output
3 Phase
A
-
-
-
-
46
41
24
21
66
59
34
30
Welding Output
Duty Cycle 100%
1 Phase
A
Duty Cycle 60%
1 Phase
A
Duty Cycle at Maximum Current
1 Phase
X
Input Mains Voltage (50/60 Hz)
1 Phase
V 208 230 400 460 208 230 400 460 208 230 400 460
Input Power S1 at 100% Duty Cycle
1 Phase
kVA 9
9
10
10
13
14
14
14
13
14
14
14
Input Power S1 at 60% Duty Cycle
1 Phase
kVA 11
11
12
12
15
16
16
16
15
16
16
16
Input Power S1 at Maximum Output
1 Phase
kVA 14
13
15
15
19
20
20
20
19
20
20
20
Generator Requirement with Single Phase
1 Phase
kVA
Input Current I1 at 100% Duty Cycle
1 Phase
A
44
40
26
23
65
61
35
30
65
61
35
30
Input Current I1 at 60% Duty Cycle
1 Phase
A
52
47
31
26
74
68
40
35
74
68
40
35
Input Current I1 Maximum Output
1 Phase
A
70
58
38
32
92
85
50
43
92
85
50
43
30
PowerMaster Power Source Part Numbers
W1000402
W1000602
Remote Power Supply with Integrated Torch Water Cooling System
Compact Power Supply with Integrated Wirefeeder
Automation Power Supply with Integrated Torch Water Cooling System
W1000502
30
23
Electrical Specifications for GMAW-P / GMAW / FCAW / MIG with Three-Phase Input Power
25
35
320SP
400SP
500SP
320SP
0.99
0.99
0.99
79
14.3 – 34
14.3 – 30
W1000202
Input Mains Power
320SP 400SP
500SP
Summary Specifications
320
79
280
W1000102
W1000304
Fan Cooled
5 – 400
10-380
-
500SP
320
400SP
350
50%@400A, 34V
60%@500A, 39V
320
Input Mains Power
350
Electrical Specifications for GMAW-P / GMAW / FCAW / MIG with Single-Phase Input Power
250
-
40%@320A, 30V
50%@400A, 34V
79
400
500
5 – 500
14.3 – 39
IP23
<70
IP23
-
+/- 10
10-300
F
Fan Cooled
<70
5 – 320
-
+/- 10
350
50%@400A, 34V
+/- 10
F
Fan Cooled
10-480
<70
IP23
F