09 power supply specifications (part 2), 09 power supply specifications (part 2) -7 – Tweco 500SP PowerMaster User Manual

Page 23

Advertising
background image

POWERMASTER 320SP, 400SP, 500SP

March 16, 2007

2-7

2.09 Power Supply Specifications (part 2)

Welding Output

Duty Cycle 100%

3 Phase

A

Duty Cycle 60%

3 Phase

A

Duty Cycle at Maximum Current

3 Phase

X

Input Mains Voltage (50/60 Hz)

3 Phase

V

-

-

-

-

208 230 400 460 208 230 400 460

Input Power S1 at 100% Duty Cycle

3 Phase

kVA -

-

-

-

10

10

11

11

16

16

17

17

Input Power S1 at 60% Duty Cycle

3 Phase

kVA -

-

-

-

12

12

12

12

23

22

22

23

Input Power S1 at Maximum Output

3 Phase

kVA

-

-

-

-

16

16

16

17

23

22

22

23

Generator Requirement with Three Phase

3 Phase

kVA

Input Current I1 at 100% Duty Cycle

3 Phase

A

-

-

-

-

27

26

16

13

44

41

25

22

Input Current I1 at 60% Duty Cycle

3 Phase

A

-

-

-

-

33

30

17

15

63

56

32

29

Input Current I1 at Maximum Output

3 Phase

A

-

-

-

-

44

40

24

21

63

56

32

29

Welding Output

Duty Cycle 100%

1 Phase

A

Duty Cycle 60%

1 Phase

A

Duty Cycle at Maximum Current

1 Phase

X

Input Mains Voltage (50/60 Hz)

1 Phase

V 208 230 400 460 208 230 400 460 208 230 400 460

Input Power S1 at 100% Duty Cycle

1 Phase

kVA 10

10

12

12

13

14

13

13

13

14

13

13

Input Power S1 at 60% Duty Cycle

1 Phase

kVA 12

12

14

13

15

15

15

15

15

15

15

15

Input Power S1 at Maximum Output

1 Phase

kVA 14

13

15

15

19

19

19

19

19

19

19

19

Generator Requirement with Single Phase

1 Phase

kVA

Input Current I1 at 100% Duty Cycle

1 Phase

A

49

45

29

25

64

59

34

29

64

59

34

29

Input Current I1 at 60% Duty Cycle

1 Phase

A

57

52

34

28

73

66

38

33

73

66

38

33

Input Current I1 at Maximum Output

1 Phase

A

67

57

38

32

90

83

48

41

90

83

48

41

Torch Cooling System (Where Fitted)

Standard Coolant Flow Rate

gallon / min.

Maximum Coolant Pressure

Psi

Pump Type

Dimensions and Weights

Power Supply Dimension

(DxWxH)

in

Power Supply Weight

lb

25

43.9x17.5x33.7

222

Input Mains Power

50

Centrifugal Pump

320SP

35

-

400SP

320SP 400SP

500SP

500SP

0.29

77

201

-

0.29

-

29.3x13.4x19.6

-

50

Centrifugal Pump

43.9x17.5x33.7

22

30

30

40%@300A, 32V

50%@380A, 35.2V 50%@380A, 35.2V

Input Mains Power

230

300

300

260

330

330

320SP 400SP

500SP

Electrical Specifications for SMAW / STICK with Single-Phase Input Power

50%@380A, 35.2V 60%@480A, 39.2V

-

-

330

480

Electrical Specifications for SMAW / STICK with Three-Phase Input Power

-

300

380

320SP 400SP

500SP

Advertising