POWERMASTER 400SP, 500SP AUTOMATION

3-8

March 16, 2007

B. How To Connect The Work lead

Connect the work lead to the Negative connection and
fasten it by turning the connector to the right. Connect
the Work clamp to the workpiece or the welding table.

Art # A-06366

Negative
Connection

Work Lead

C. Where to connect the Work Clamp

Fasten the Work clamp (shown as #2 below), near the
welding location; this avoids stray current flow through
mains earthing system.

Art # A-06367

2

1

1

L

L

L

N

E

1

Connect the Work clamp tightly to the welding bench
or to the workpiece.

!

WARNING

Do not place the Work clamp on the welding
power supply or gas cylinder as welding
current may be conducted via the mains
earth and will burn it out.

D. How To Connect To The Mains

Refer to Connecting Input Power Section.

E. How To Install The Wire Spool

Open the wire feed compartment lid on the power
supply or wirefeed case and un-screw the nut from
the wire support coil hub.

Place wire spool on the hub and ensure that the drive
dog-pin engages the mating hole in the wire spool.

Press then release the inch switch

to adjust the

brake, the wire spool should not continue to run.

Art # A-06368

Drive pin

Hub

Brake

Nut

Advertising