12 grounding the generator – Tweco Raider 10,000 Pro User Manual

Page 16

Advertising
background image

18

2.11 Wiring Optional 230

Volt Plug

The plug can be wired for a 230V, 2-wire load or a
115/230V, 3-wire load. See diagram below

White - Neutral terminal.
YYY - Load 1 terminal.
XXX - Load 2 terminal.
Green - Ground terminal.

Select proper insolated and grounded equipment.

1) Auxiliary power receptacles are Neutral bonded to

frame.

2) 3-Prong plug for case Grounded equipment
3) 2-Prong plug for double insulated equipment.

2.12 Grounding The

Generator

TO A TRUCK OR TRAILER FRAME
1. Generator base.
2. Metal vehicle frame.
3. Equipment grounding terminal.
4. Grounding cable. Use # 10 AGW or larger insulated

copper wire.

NOTE: FOR THE GFCI RECEPTACLES TO
PERFORM PROPER PROTECTION THE WELDING
GENERATOR MUST BE EARTH GROUNDED.

TECHNICAL SPECIFICATIONS

Advertising