12 grounding the generator – Tweco Raider 10,000 Pro User Manual
Page 16
Advertising
18
2.11 Wiring Optional 230
Volt Plug
The plug can be wired for a 230V, 2-wire load or a
115/230V, 3-wire load. See diagram below
White - Neutral terminal.
YYY - Load 1 terminal.
XXX - Load 2 terminal.
Green - Ground terminal.
Select proper insolated and grounded equipment.
1) Auxiliary power receptacles are Neutral bonded to
frame.
2) 3-Prong plug for case Grounded equipment
3) 2-Prong plug for double insulated equipment.
2.12 Grounding The
Generator
TO A TRUCK OR TRAILER FRAME
1. Generator base.
2. Metal vehicle frame.
3. Equipment grounding terminal.
4. Grounding cable. Use # 10 AGW or larger insulated
copper wire.
NOTE: FOR THE GFCI RECEPTACLES TO
PERFORM PROPER PROTECTION THE WELDING
GENERATOR MUST BE EARTH GROUNDED.
TECHNICAL SPECIFICATIONS