Installation/setup transmig 250i – Tweco 250i Multi Process Welding Inverter 2RT Wire Feeder User Manual

Page 29

Advertising
background image

INSTALLATION/SETUP

TRANSMIG 250i

Manual 0-5187

3-11 INSTALLATION/SETUP

LIFT TIG

If the welder is in Advanced Features mode and the Weld Process Selection button (Control No 4) is pressed, the

welder will exit Advanced Features mode, saving any change made, and change to the next weld process function in

the sequence: MIG, TIG, stick. If you wish to view the Advanced Features for the next process you will need to enter

the Advanced Features function again.

Push For Inductance

Arc Control

Right Knob

If the welder is in Advanced Features mode and the right knob (Control No 8) is pressed for one (1) second (to enter

Arc Control Function) the welder will exit Advanced Features mode, saving any change made, and enter the Arc Control

Function for the currently selected weld process.

NOTE

The "LOCL/REMT" settings will revert to the factory default setting each time the weld process is changed.

A setting other than the default will only be remembered while in that process.

MIG (GMAW/FCAW)Mode Advanced Features Menu Map

RUN- / IN

POST / FLOW

BURN / BACK

WIRE / SHRP

Advanced Menu – MIG

Mode

Wire Feed Speed

ARC- / TYPE

MIG / CNTL

PRE- / FLOW

SPOT

STCH

DWEL / TIME

ON OFF

*STCH / TIME

AUTO CV

Advanced Menu - MIG

Options or Range

Press Advanced Button

to Exit to Welding Mode

LOCL REMT

0.1 - 5.0 S

MPM IPM

WFS- / UNIT

30 - 150%

0.0 - 30.0 S

0.00 - 1.00 S

0.1-20.0 S

FACT / DFLT

HR

*SPOT / TIME

0.2 - 4.0 S
0.1 - 1.0 S

0.0 - 9999.9

NO YES

Press Advanced Button

to Exit to Welding Mode

Left Display

Right Display

ON OFF

ON OFF

Left Knob Selection

* SPOT TIME and STCH TIME are only active when SPOT or STCH are “ON”.

Note “SPOT” and “STCH” are MUTUALLY EXCLUSIVE functions. If the user enables either function and the system

detects that the OTHER function is already ON, the system will automatically turn the OTHER conflicting function OFF.

Left Display: Where (2) items shown, e.g. RUN- / IN, the display will alternate (flash) between the (2) items

Right Knob Selection

Art # A-10321

Figure 3-5 MIG Advanced Menu

Advertising