SERVICE

FIREpOwER Fp-95

Service

5-3

Manual 0-5122

5.05 Power Source Problems

FAULT

CAUSE

REMEDY

1

Primary line voltage is

ON. Welding arc can not

be established.

A Primary fuse is blown.

A Replace primary fuse.

B Broken connection in pri-

mary circuit.

B Have an Accredited THERMAL ARC Service Agent check

primary circuit.

2

Primary line voltage is

ON but when the MIG

Gun trigger switch is

depressed nothing hap-

pens.

MIG Gun trigger switch leads

are disconnected.

Reconnect.

3

Primary line voltage is

ON, no wire feed but gas

flows from the MIG Gun

when the torch trigger

switch is depressed.

A Electrode wire stuck in wire

liner or contact tip (burn-

back jam).

A Check for clogged / kinked MIG Gun wire liner or worn

contact tip. Replace faulty component(s).

B Faulty control PCB

B Have an Accredited THERMAL ARC Service Agent in-

vestigate the fault.

4

Wire feeds when the

MIG Gun trigger switch

is depressed but arc can

not be established.

Poor or no work lead con-

nection.

Clean work clamp area and ensure good electrical

contact.

5

Jerky wire feed

A Worn or dirty contact tip

A Replace

B Worn feed roller.

B Replace

C Excessive back tension from

wire reel hub.

C Reduce brake tension on spool hub

D Worn, kinked or dirty conduit

liner

D Clean or replace conduit liner

6

Thermal Overtemp Light

is ON and Fan motor is

running

The machine duty cycle has

been exceeded.

Allow the fan to run so machine can cool down. When

light goes out, welding may resume.

7

Thermal Overtemp Light

turns on in less than 30

seconds during weld-

ing.

Fan has stopped running or

fuse on PCB has blown

Have an Accredited THERMAL ARC Service Agent re-

place the fuse.

Table 5-2: Power Source Problems