3. Slide the barrel rearward.

4. Guide the barrel bracket over the end of the magazine

tube and guide the barrel extension into the receiver.

Be sure that the slot in the barrel aligns with the ejec-

tor. As a guide in assembly, align the rib on the barrel

assembly with the grooves on the top of the receiver.

5. Slide the barrel rearward until it seats in the receiver.

6. Immediately replace the magazine cap. Tighten it hand

tight at least three full turns to ensure secure engagement.

T

AKEDOWN

FIRST BE CERTAIN THERE ARE NO SHELLS IN THE
MAGAZINE OR CHAMBER.

1. Depress the disconnector release button, found behind

the trigger guard on the left side (Figure 5) to unlock

the action without releasing the hammer.

2. Open the action and place the safety in the “on safe”

position. (The red warning band must not be visible.)

3. With the magazine pointed in a safe direction,

unscrew and remove the magazine cap. Be careful,

the magazine spring and magazine plug are retained

by a friction-type retainer.

ALWAYS KEEP THE MAGAZINE POINTED AWAY FROM YOU
AND OTHERS WHEN REMOVING THE MAGAZINE CAP.

4. With one hand, grasp the barrel ahead of the barrel

bracket, hold the buttstock with your other hand.

Pull the barrel to disengage it from the receiver. Slide

the barrel bracket off the magazine.

Do not use

excessive force.

Immediately replace the magazine cap

and hand tighten at least three turns.

Reassembly of the barrel to the action is explained

in the previous section.

L

OADING

P

ROCEDURES

F

IRING A

S

INGLE

S

HOT

Use the correct ammunition referenced by the inscription

on the barrel. Before loading your gun, be sure all grease

and oil have been removed from the barrel and chamber

and there are no obstructions.

Press the disconnector release

button to unlock the action.

FIGURE 5

Advertising