CCI Thermal Technologies XB - Explosion-Proof Natural Convection Heater (Optional Adjustable Temperature Control) User Manual

Page 3

Advertising
background image

3

5.0 WALL MOUNTING

5.1 Install heater with the supplied hardware in

accordance with the Figures and instructions

below.
Step 1: Secure wall and stabilizing brackets to

mounting surface (Figure 3).

FIGURE 3 - INSTALL MOUNTING BRACKET

Step 2: Position heater face down on floor

with terminal box towards mounting brackets.

(Ensure that baffles are installed [see section

3.6 of this manual]). Angle heater such that the

terminal box rests on bottom of wall bracket.

Lift top of heater and align with top stabilizing

brackets.
Secure with supplied 1/4”-20 hex bolts and

lock washers (Figure 4).

FIGURE 4 - WALL MOUNTING DIAGRAM

Step 3: Secure bottom of heater to wall

mounting brackets with supplied 1/4”-20 hex

bolts and lock washers (Figure 5).

FIGURE 5 - ATTACH HEATER TO MOUNTING BRACKETS

6.0 FLOOR MOUNTING

Step 1: Position heater face down on the floor

with terminal box towards the wall (Figure 6).

FIGURE 6 - FLOOR MOUNTING DIAGRAM

Step 2: Fasten top stabilizing bracket(s) and

floor mounting bracket(s) to the unit. Floor

mounting brackets may be mounted in one of

three orientations (Figure 7).

FIGURE 7 - INSTALL MOUNTING BRACKET TO HEATER

Step 3: Lift top of unit and position heater

vertically against the wall. Secure stabilizing

and floor mounting brackets to the mounting

surfaces (Figure 8).

FIGURE 8 - ATTACH HEATER TO FLOOR AND WALL

CAUTION

NEVER INSTALL ONE HEATER ABOVE

THE OTHER.

TO ENSURE SAFE OPERATION, HEATER

MUST BE INSTALLED, AS SHOWN IN FIGURES

5 & 8. INSTALLATION WITH FINS IN THE

INCORRECT ORIENTATION MAY RESULT IN AN

UNSAFE CONDITION (REFER TO TABLE 1).