4.0 OPERATIOn

4.1

startup:

(i) install the stratafan™ in the desired

location as per the Installation

Instructions section of the installation

& operation instructions. The fan will

start operation when the unit absorbs

sufficient heat from the heater. Under

normal operating conditions with the

heater at steady-state temperature, the

fan should reach continuous operating

speed within approximately 5 minutes.

The stratafan™ does not require any

assistance for start-up.

4.2

shutdown:

(i) To stop the fan, the heater must be

turned off. The fan will slow to a stop

once it cools off.

CAuTIOn

ThE sTRATAfAn™ InCLudEs ROTATInG

COmPOnEnTs And CARE shOuLd bE

TAkEn AROund ThE unIT. dO nOT

InsERT fInGERs OR OThER ObjECTs

InTO ThE fAn WhILE ThE unIT Is

In OPERATIOn. dO nOT bLOCk AIR

fLOW by PLACInG mITTs OR OThER

ObjECTs On TOP OR In fROnT Of ThE

WIRE GRILLE.

WARnInG

PLACInG A hOT fAn On A suRfACE

mAy REsuLT In PROPERTy dAmAGE,

fIRE OR InjuRy. dO nOT TOuCh ThE

sTRATAfAn™ WhILE In OPERATIOn.

5.0 InsTALLATIOn InsTRuCTIOns

5.1

General Instructions:

(i) start your cata-dyne™ heater and

let reaction fully develop for at least

30 minutes.

(ii) The stratafan™ must be installed on

a csa approved WX or MKii model

cata-dyne™ heater with a maximum

input capacity of 5,000 Btu/hr for every

square foot of pad area. for example,

the Stratafan™ is certified for use on a

WX 12x24 heater rated to 10,000 Btu/

hr, this WX heater will have two square

feet of pad area at 5,000 Btu/hr for every

square foot.

(iii) determine where you would like to

mount the unit on the heater. The ideal

mounting position for the stratafan™

is on the top. if you have a vent-hood,

mount the unit on the side or bottom.

5.2

Top Installation:

heat Collection Plate

(i) place on top of the unit with the heat

collection plate directly in front of the

pad surface.

CAuTIOn

dO nOT PuT sTRATAfAn™ OvER TOP

Of ThE suPPORTInG RAIL.

use a 5/32”

allen key

(ii) clamp the stratafan™ to the heater box

by tightening the hex head socket cap

screws using a 5/32” allen key.

use a 7/64” allen key

(iii) secure the stratafan™ to the

cata-dyne™ unit heater by tightening

the cone head set screws using a 7/64”

allen key.

separate Installation and Operation Instructions are available for industrial heating applications.