INSTALLING THE AT10.1

3

1.4. MOVING THE AT10.1

Once you have established that the AT10.1 is undamaged, identify the
enclosure style and weight of your unit. Refer to the table below.

AT10.1 Enclosure Style and Shipping Weight Table

Group I NEMA-1 Cabinets (Style-586 / Style-594)

Ampere Rating

Output

Voltage

6 Adc

12 Adc

16 Adc

20 Adc

25 Adc

12 Vdc

Style-586

44 lbs

20 kg

Style-586

44 lbs

20 kg

Style-586

67 lbs

30 kg

Style-586

67 lbs

30 kg

Style-586

67 lbs

30 kg

24 Vdc

Style-586

44 lbs

20 kg

Style-586

58 lbs

26 kg

Style-586

75 lbs

34 kg

Style-586

75 lbs

34 kg

Style-586

75 lbs

34 kg

48 Vdc

Style-586

58 lbs

26 kg

Style-586

75 lbs

34 kg

Style-594

110 lbs

50 kg

Style-594

110 lbs

50 kg

Style-594

110 lbs

50 kg

130 Vdc

Style-586

80 lbs

36 kg

Style-594

147 lbs

67 kg

Style-594

193 lbs

88 kg

Style-594

193 lbs

88 kg

Style-594

193 lbs

88 kg

NOTE: Actual unit is approximately 20 lbs / 9kg below listed shipping weight in table.

The AT10.1 Style-586 & Style-594 enclosures do not feature lifting eyes
for moving. Whenever possible, move the unit with a forklift truck, using
the supplied shipping pallet. To lift or relocate the AT10.1 into a wall-
mount or rack-mount location, use a heavy-duty sling on a hoist or forklift
truck applicable for the enclosure size and unit weight listed above.

For further AT10.1 standard cabinet information, see the outline drawings
for the Style-586 (

JE5023-03

) and Style-594 (

JE5024-03

) enclosures in

Appendix C on pages 72 and 73.

1.5. MOUNTING THE AT10.1

Chose the mounting method for the unit enclosure from the table below.

ENCLOSURE

MANUAL

SECTION

MOUNTING METHOD

Style-586 Style-594

1.5.1 Wall-Mounting

STANDARD STANDARD

1.5.2 Floor-Mounting

OPTIONAL

OPTIONAL

19in / 483mm Rack-Mounting

OPTIONAL

N/A

1.5.3

23-24in / 584-610mm

Rack-Mounting

OPTIONAL OPTIONAL