Standard system components, Linear probe array, Y axis scanner – ORBIT FR T-DualScan User Manual

Page 4: Antennas, X axis scanner, Absorbers and anechoic chamber, Dut positioning equipment, I t-dualscan

Advertising
background image

121

Standard system components

Linear probe
array

From 1 to 12 meters long

probe-array (StarLine)
It includes by default interleaved
probes to cover 0.8 to 18 GHz.

70 - 400 MHz probe array

available on demand

Y axis scanner

1 to 15 meter high tower scanner

Probe roll positioner

ORBIT/FR positioning

equipment catalog

Antennas

A complete range of measurement

probes (single or dual polarized)
and reference antennas (horns,
standard gain horns) are
available

MVG antenna catalog

X axis scanner

X Axis length depends

on customer requirement

Absorbers

and anechoic
chamber

An optimized combination of

standard, adapted and specialty
absorbers

Anechoic chamber with

integrated design, production,
installation and testing services

AEMI absorber catalog

DUT positioning
equipment

A complete range of rotary

positioners and model towers are
available with air cushion (optional)

ORBIT/FR positioning

equipment catalog

I T-DualScan

Quick guide to evaluate scan

area requirement

The required scan area is calculated according to the following
formula: Scan length = D + 2 L tg (

a

)

Where:
-

a

is the relevant data angle in far-field

- L, the distance between the probe and the AUT
- and D, the antenna size.

Sampling principle

Sampling step is based on the minimum measured
wavelength (

l

min

).

D

sampling

= (

l

min

/2)

Probe

Probe

L

Distance from

AUT to Probe

Scan Length

D

A
U
T

a

a

6

4

3

Advertising