Measurement time comparison, I t-dualscan, System specifications multi-probe set-up – ORBIT FR T-DualScan User Manual

Page 5: Typical measurement time for single beam antenna, Multi-probe set-up, System specifications single-probe set-up, Single-probe set-up

Advertising
background image

122

System specifications Multi-probe set-up*


30 dBi AUT

PEAK GAIN ACCURACY

0.8 GHz - 1 GHz

± 0.5 dB

1 GHz - 6 GHz

± 0.5 dB

6 GHz - 18 GHz

± 0.5 dB

Repeatability

± 0.3 dB

- 20 dB SIDELOBES ACCURACY

0.8 GHz - 1 GHz

± 0.6 dB

1 GHz - 6 GHz

± 0.6 dB

6 GHz - 18 GHz

± 0.7 dB

- 30 dB SIDELOBES ACCURACY

0.8 GHz - 1 GHz

± 1.3 dB

1 GHz - 6 GHz

± 1.2 dB

6 GHz - 18 GHz

± 1.3 dB

* Table refers to radiation pattern < ± 60 deg. Specifications given according
to the following assumptions:
• Controlled temperature and humidity during measurement
• Specifications on radiation pattern are given for a normalized pattern
• Measurements inside an anechoic chamber
• Peak gain is given for a ± 0.3 dB gain error on the reference antenna
• No averaging

Typical measurement time for single beam antenna

(1)

Multi-probe set-up*

Frequency

Number of measured

Measurement

frequencies

time (in hours)

3 GHz

5

0.1

3 GHz

10

0.2

18 GHz

5

3

18 GHz

10

4.5

(1) AUT size 5 x 5 m

System specifications

Single-probe set-up*


30 dBi AUT

PEAK GAIN ACCURACY

0.8 GHz - 1 GHz

± 0.5 dB

1 GHz - 6 GHz

± 0.5 dB

6 GHz - 18 GHz

± 0.5 dB

18 GHz - 40 GHz

± 0.5 dB

Repeatability

± 0.3 dB

- 20 dB SIDELOBES ACCURACY

0.8 GHz - 1 GHz

± 0.5 dB

1 GHz - 6 GHz

± 0.5 dB

6 GHz - 18 GHz

± 0.5 dB

18 GHz - 40 GHz

± 0.5 dB

- 30 dB SIDELOBES ACCURACY

0.8 GHz - 1 GHz

± 1.2 dB

1 GHz - 6 GHz

± 1.0 dB

6 GHz - 18 GHz

± 1.1 dB

18 GHz - 40 GHz

± 1.3 dB

* Table refers to radiation pattern < ± 60 deg. Specifications given according
to the following assumptions:
• Controlled temperature and humidity during measurement
• Specifications on radiation pattern are given for a normalized pattern
• Measurements inside an anechoic chamber
• Peak gain is given for a ± 0.3 dB gain error on the reference antenna
• No averaging

Typical measurement time for single beam antenna

(1)

Single-probe set-up*

Frequency

Number of measured

Measurement

frequencies

time (in hours)

3 GHz

5

2

3 GHz

10

2.5

18 GHz

5

21

18 GHz

10

23

(1) AUT size 5 x 5 m

Measurement time comparison

5

I T-DualScan

Advertising