Vermont Casting 2479 User Manual

Page 14

Advertising
background image

14

Dutchwest Non-Catalytic Convection Heater

30002291

Distance from Center of Flue Collar to Wall in Top-Exit Installations

Dutchwest Convection Heater Model 2479
NOTE: These are not clearance distances. These measurements indicate where the centerline of the flue col-
lar will be for various installations. Measurements are from the centerline of the flue collar to the wall, not the
wall protector.

ST427

dutchwest

flue centerline

6/30/00 djt

A

B

C

E

D

F

C

F

Chimney Connector

Side

Rear

Corner

Side

Rear

Corner

Listed, Approved

(A) 34¹⁄₂”

(B) 12¹⁄₂”

(C) 21”

(D) 22¹⁄₂”

(E) 12”

(F) 20¹₂”

Double-wall, with

(846 mm)

(318 mm)

(533 mm)

(572 mm)

(305 mm)

(521 mm)

flue collar shield
Single wall, with

(A) 29¹⁄₂”

(B) 12¹⁄₂”

(C) 21”

(D) 22¹⁄₂”

(E) 9¹⁄₂”

(F) 18¹⁄₂”

Connector heat shields

(749 mm)

(318 mm)

(533 mm)

(572 mm)

(241 mm)

(570 mm)

and flue collar shield
Single wall with no

(A) 35¹⁄₂”

(B) 23¹⁄₂”

(C) 30”

(D) 22¹⁄₂”

(E) 17¹⁄₂”

(F) 25”

heat shields

(902 mm)

(967 mm)

(762 mm)

(572 mm)

(445 mm)

(635 mm)

UNPROTECTED SURFACES

PROTECTED SURFACES

Corner

Corner

Parallel Installations

Installations Parallel Installations

Installations

ST427

Advertising