5

HL5401, HX5400 Series

www.chpower.com

Operation

beFOre FIrSt Start-Up
break-In prOCeDUre
(Complete this procedure before using
compressor for the first time. Once
completed, it is not necessary to repeat.)
1. Open drain valve located on bottom

of tank.

2. Turn On / OFF switch to OFF

position.

3. Plug in power cord.
4. Turn On / OFF switch to On position

and run compressor for 30 minutes.

5. Turn On / OFF switch to OFF

position.

6. Unplug power cord.
7. Close drain valve.
The compressor is now ready for use.

OperatInG prOCeDUre
1. Turn switch to OFF position and plug

in power cord.

2. Turn regulator knob

counterclockwise to close air flow.

3. Turn switch to aUtO position.
4. Compressor will build to maximum

pressure and shut off.

5. With hose attached to outlet of

compressor, attach tire chuck or
other tool to open end of hose.

6. Adjust regulator to proper pressure

for tool or tire. Operate tool per
instructions.

As air is depleted from the tank by
use of a tire chuck, tool, etc., the
compressor will restart automatically
at its preset “cut-in” pressure. When
a tool is being used continuously,
the compressor will cycle on and off
automatically.
7. Turn switch to OFF position, unplug

power cord and drain tank of air
when finished using compressor.

Maintenance

Disconnect, tag and lock out
power source, then release
all pressure from the system
before attempting to install, service,
relocate or perform any maintenance.

Check compressor often for any visible
problems and follow maintenance
procedures each time compressor is
used.

aSMe SaFety vaLve

Do not remove or

attempt to adjust

the safety valve!

Check the safety valve by performing
the following steps:

1. Plug the compressor in and run until

shut off pressure is reached.

2. Wearing safety glasses, pull the

ring on the safety valve to release
pressure from compressor tank. Use
your other hand to deflect fast-
moving air from being directed
toward your face.

3. The safety valve should

automatically close at approximately
40 psi - 50 psi. If the safety valve
does not allow air to be released
when you pull on the ring, or if
it does not close automatically, it
MUST be replaced.

Safety valve must be

replaced if it cannot

be actuated or it leaks air after ring is
released.

Figure 8

DraIn tank
1. Turn compressor off and release

pressure from system. (To release
pressure from system, pull ring on
ASME safety valve. Deflect escaping
air by shielding valve with one hand
as you pull ring with other hand.)
Pull ring until tank is empty.

A large amount of

fast moving air will

be released when the safety valve is
opened with pressure in the tank. Wear
ANSI approved Z87.1 safety glasses.

2. Drain moisture from tank by

opening drain valve underneath
tank. Tilt tank to remove all
moisture.

3. Clean dust and dirt from tank,

air lines and pump cover while
compressor is still OFF.

OIL CHanGe
1. Allow compressor to run and warm

up oil. Unplug unit.

2. Position a pan under pump end of

unit.

3. Remove drain plug. Allow oil to

collect in pan. Tilt unit to completely
drain.

4. Replace drain plug, fill pump to

center of sight glass. Use Chevron
synthetic 5W-30, Mobil 1 5W-30 or
10W-30 synthetic motor oil. Using
other types of oil will cause starting
problems.

5. Change oil after every 50 hours of

use.