troubleshooting Chart

(Continued)

Symptom

possible Cause(s)

Corrective action

Tank pressure drops when
compressor shuts off

1. Circuit overloaded

1. Disconnect other electrical appliances from circuit or

operate compressor on its own branch circuit

2. Low voltage

2. Check voltage at wall outlet with voltmeter.

3. Extension cord usage - wrong

gauge wire and/or too long.

3. Remove extension cord or refer to Extension Cord Chart on

page 4

4. Loose electrical connections

4. Check all electrical connections

5. Worn check valve

5. Replace check valve

Do not disassemble check valve with

air pressure in tank; bleed tank.

6. Defective unloader valve (on

pressure switch)

6. Replace unloader valve

7. Defective motor capacitor(s)

7. Replace capacitor(s)

8. Defective motor

8. Replace motor

Compressor runs
continuously and air
output is lower than
normal/low discharge
pressure

1. Lack of proper ventilation /

room temperature too high

1. Move compressor to well ventilated area

2. Clogged intake filter

2. Clean or replace filter

3. Circuit overloaded

3. Check for proper fuse, use time-delay fuse. Disconnect

other electrical appliances from circuit or operate

compressor on its own branch circuit

4. Extension cord usage - wrong

gauge wire and/or too long.

4. Remove extension cord or refer to Extension Cord Chart on

page 4

5. Worn check valve

5. Replace check valve

Do not disassemble check valve with

air pressure in tank; bleed tank.

6. Defective unloader valve (on

pressure switch)

6. Replace unloader valve.

7. Defective motor

7. Replace motor

Knocks, rattles, and/or
excessive vibration

1. Loose mounting bolts

1. Tighten bolts.

2. Tank not level

2. Use sturdy wedge/object to bring tank to level position.

3. Cylinder or piston is worn/

scored

3. Replace or repair as necessary.

Compressor runs
continuously and safety
valve opens as pressure
rises

1. Defective pressure switch

1. Replace switch.

2. Defective safety valve

2. Replace safety valve with genuine replacement part.

Air leaking from
unloader valve on
pressure switch

1. Check valve stuck in an open

position

1. Replace check valve.

2. Unloader valve stuck in open

position

2. Replace unloader valve.

Do not disassemble check valve with

air pressure in tank; bleed tank.