SARGENT BT- Beacon User Manual
Page 4
Copyright © 2013 Sargent Manufacturing Company
, an ASSA ABLOY Group company
. All rights reser
ved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
02/01/13
4 A7974C
Beacon Exit Device
Installation and Wiring Instructions
FOR INSTALLATION ASSISTANCE CONTACT SARGENT • 1-800-810-WIRE (9473) • www.sargentlock.com
• Easily installed within all 80 Series Exit Devices as either a retrofit kit or
as a factory installed option (consult catalog for exceptions).
• Order kit as 548-Kit (x door width x finish). See table below.
• Order factory installed option as
BT- (e.g. BT-8813F x ETL x 32D x 36” door)
• Door Widths: Minimum Wide Stile Door 32”
• Convenient wiring installation with ElectroLynx 8-pin & 4-pin connectors*
2. Hardware Specifications
Stile
Rail
Size
Type of
Exit Device
Size
Door
Wide
E
80 Series Exit
Devices
32”
only
F
35”- 36”
J
38”- 42”
G
44”- 48”
Narrow
E
30”- 32”
F
33”- 36”
J
37”- 42”
G
43”- 48”
Note: The Beacon Retrofit Kits can NOT be
added to FM8700 Devices, Low Profile Exits
and devices with Cylinder Dogging (16-).
548- Retrofit Kits replace Beacon BT- ONLY
products (without other electrical prefixes).
For existing TL- BT-, consult factory.
The Retrofit Kits are based on rail design
(wide or narrow) and dimension from pivot
to pivot.
Kit #
Device Stile Rail Size
Pivot to Pivot
*
548-1 Wide
F
11-1/4”
548-2 Narrow
F
11-1/4”
548-3 Wide
G
20-1/2”
548-4 Narrow
G
20-1/2”
548-5 Wide
E
8-1/2”
548-6 Narrow
E
8-1/2”
548-7 Wide
J
14”
548-8 Narrow
J
14”
Wide Stile
Narrow Stile
*
Pivot-to-Pivot
Dimension
*ElectroLynx door & frame wire harnesses and power transfer devices must be ordered separately.
Refer to McKinney Power Transfer Device Catalog for further information.
Field-cut rail assemblies are not allowed.
The exit device must be ordered from
factory for specific door widths.
Fig. 2