ALL MODELS: RS-232 PORT
CONNECTING WITH TELNET

Users can connect to any unit via RS-232 and telnet. Available telnet commands are the same as those used in
the Serial Command section of this appendix.

How to Connect with Telnet:

• Use the telnet client of your choice
• Telnet uses port 23
• The user name and password are the same as used by Console. The default username is clearone and

the default password is converge. These are not case sensitive.

• The telnet session will time out after 15 minutes of no receive data. A heart beat to keep the session alive

will need to be used. ClearOne recommends using the VER command to establish a heart beat in order to
keep the session alive.

ALL MODELS: RS-232 PORT

Pin #

User Definable

Control

1

N

DCD

2

N

TXD

3

N

RXD

4

N

DTR

5

N

Ground

6

N

DSR

7

N

CTS

8

N

RTS

9

N

No connection

NOTE: To avoid communication errors, ClearOne recommends using all nine pins when

connecting to the RS-232 port.