Clamp-on angle ring, Powerhead, Clamp-on angle ring 3.3. powerhead – Wheatheart Galvanized Utility Auger User Manual

Page 14

Advertising
background image

3. A

SSEMBLY

W

HEATHEART

- G

RAIN

A

UGERS

3.2. C

LAMP

-O

N

A

NGLE

R

ING

U

TILITY

14

30644 R1

5. For additional tube/flight

sections, repeat steps.

3.2. CLAMP-ON ANGLE RING

1. Slide

clamp-on angle ring onto

the end of the galvanized tube
(Figure 3.3).

2. Slide ring on until the end of the

angle ring is flush with the end
of the tube. Secure angle ring to
the tube using six 7/16” x 1"
bolts and whiznuts; tighten bolts
and nuts securely.

3. Secure second clamp-on angle

ring on opposite end of
galvanized tube following steps
1 and 2.

3.3. POWERHEAD

See Figure 3.4.

1. Pull flighting out of the galvanized tube enough to obtain access to the 2

holes at the end of the flighting pipe.

2. On powerhead, remove bearing collar from the flighting shaft. Slide

powerhead flighting out of tube and attach to the flighting of galvanized tube.
Ensure that the 2 flightings overlap. Use two 7/16” x 2-1/4” (for 8") or two 1/2”
x 2-3/4” (for 10") bolts and locknuts and tighten securely.

3. Re-install flighting onto powerhead tube and replace bearing collar onto

flighting stub shaft.

4. Connect the 2 angle flanges together using eight 7/16” x 1" bolts and

locknuts. Tighten securely.

Figure 3.2

Figure 3.3

Advertising