Proper burner flame, Burner orifice, Page 13 – Louisville Tin and Stove BBT104 User Manual

Page 13: Figure 12 figure 11, Figure 13

Advertising
background image

NATURAL GAS

BBT53

5 6

5 7

5 7

5 9

6 0

BBT103

1.45mm 5 4

5 4

5 5

5 5

L.P. GAS

BBT54

7 0

7 1

7 1

7 2

7 3

BBT104

6 3

6 5

6 5

6 6

6 8

ORDER KIT #49800 44-1 HIGH ALTITUDE KIT FOR NAT. OR L.P.
GAS.

MODEL

0 to

2,000’

4,000’

6,000’

8,000’ -

NO.

2,000’

4,000’

6,000’

8,000’

10,000’

PROPER BURNER FLAME

The burner flame may be observed through the sight glass
located in the burner box cover. See Figure 11. A proper
flame will have a dark blue inner mantle, with a lighter blue
outer mantle that extends from the burner into the heat
exchanger tube, (see Figure 12). There is no primary air
adjustment on the burner, and proper flame is assured since
the correct manifold pressure and orificing has been done
at the factory for elevations up to 2,000 feet.

TO REMOVE MAIN BURNER FOR

INSPECTION AND CLEANING

a.

Turn off all electrical supply to heater.

b.

Turn off gas supply.

c.

Remove cabinet cover.

d.

Remove burner box cover. See Figure 13.

e.

Remove two (2) screws holding burner to burner
bracket. See Figure 13.

f.

Burner can now be slid forward off orifice, lift
up, slide back and out of burner box.

g.

Clean or replace as needed.

h.

Reinstall by reversing Steps “f” through “a”.

BURNER ORIFICE

This heater is orificed at the factory for elevations up to
2,000 ft. If installed above 2,000 ft., the BTU input must
be reduced 4% per 1,000 ft. See the following orifice chart
for the proper orifice for a specific elevation.

SPECIFIC ELEVATIONS

Page 13

COMBUSTION

TUBE

BURNER

BURNER FLAME

FIGURE 12

FIGURE 11

BURNER BOX

COVER

SIGHT

GLASS

Burner Box

Burner Orifice

Burner

Burner Access

Plate

Sight

Glass

Burner

Bracket

FIGURE 13

Sight Glass