Page 6 optional kits, Installation, Step 1 – Louisville Tin and Stove BBT104 User Manual

Page 6: Figure 2, Floor

Advertising
background image

Page 6

OPTIONAL KITS

For special installation applications and modifications, the following kits are available from your local dealer. To
ensure safe, efficient operation of your Direct Vent Gas Baseboard be sure to use only authorized kits.

Table 1: Special adaptation and modification kits available for use with the Direct Vent Baseboard Heaters.

MODEL #

DESCRIPTION

CONTENTS

VWSK5/10

Vent Weather Seal Kit

2” diameter PVC pipe, external wall seal, O-ring, 2 PVC straps,
PVC glue, instructions.

VRK5/10

Vent Riser Kit

Wall mount plate, 21-1/2” stainless steel vent riser, instructions

SVCK5/10

Side Valve Concealer Kit

4” cabinet extension, wall plate, screws, instructions

BVCK5/10

Bottom Valve Concealer Kit

4” cover, wall plate, screws, instructions

INSTALLATION

WARNING:

Failure to follow these instructions carefully could result in poor performance, property damage,
personal injury, or loss of life.

STEP 1.

LOCATE VENT OPENING (Requires a 2-1/2” hole when not using vent weather seal kit).

a)

Select area on wall where heater will be installed.

b)

Check outside vent termination for proper clearances. See Figure 1.

c)

Locate studs behind heater location.

d)

Using template supplied, mark location for 2-1/2” hole between studs. See Figure 2.

e)

Cut vent openings through both the inside and outside walls, being sure to maintain level
across both openings.

FLOOR

FIGURE 2

RIGHT END OF HEA

TER

VENT HOLE LOCATION FOR THE AIR
INTAKE AND EXHAUST TUBES FOR
STANDARD INSTALLATION 2-1/2” DIA.
HOLE. NOTE: 3” DIA. HOLE REQUIRED
FOR WEATHER SEAL KIT.

11-3/8”

7-3/4”

FLOOR

Advertising