CTs 2-Channel Power Amplifiers

Operation Manual

CONDITION: No sound, even though
the amp has power.
Power LED is on with-
out flashing and the amp is receiving an input sig-
nal. Signal indicator is flashing.

POSSIBLE REASON:

Speakers not connected.

Open circuit due to speaker failure.

There is a short on the amplifier output. First

disconnect your speakers from the affected
channel(s) one by one to determine if one of
the loads is shorted.

CONDITION: No input signal. Signal
indicator is not flashing even though audio is
applied, and the channel is ready..

POSSIBLE REASON:

Input signal level is very low.

Level controls are turned down.

CONDITION: Data indicator not flash-
ing, even though PIP module is
installed and host computer control
software is active.

POSSIBLE REASON:

Cable between computer and PIP module is

broken or not connected.

Note: Data indicator flashes only when the installed
PIP2 module is polled for data, or is polled to see
whether it is online.

6 Troubleshooting

“Off/Flashing/On” above means that
the LED can be off, or flashing, or on.

Ready LED is off. Channel has been set to
standby mode via the control system.

CONDITION: Bridge LED is lit.

POSSIBLE REASON:

Amplifier is in bridge-mono mode.