Xx xx xx, Put 1 to 64 3-byte commands here – Aphex 5200 RC Interface User Manual

Page 8

Advertising
background image

Aphex Remote Pre Parametric MIDI Commands

Command

Control

Value Range

00h

Input Gain

1Ah to 41h (26 to 65)

01h

Main Max Out

00h to 1Bh (0 to 27)

02h

Aux Max Out

00h to 1Bh (0 to 27)

03h

Phantom Power

00h = OFF, 01h = ON

04h

Low Cut Filter

00h = OFF, 01h = ON

05h

Limiter (MicLim)

00h = OFF, 01h = ON

06h

Polarity Reverse

00h = OFF, 01h = ON

07h

Mute

00h = OFF, 01h = ON

08h

Pad

00h = OFF, 01h = ON

0Ah

Test Tone -20dB

00h = OFF, 01h = ON

0Bh

Test Tone 0dB

00h = OFF, 01h = ON

17h

Test Tone (alternative method)

00h = OFF, 01h = -20dB, 02h = 0dB

20h

Request Parameter SysEx Dump

01h (required)

56h

Request Extended SysEx Dump

00h (any value placeholder byte)

F0 00 00 38 xx xx

xx xx xx

F7

SysEx Start

MIDI Channel

MIDI Device

xx

Net Number

Command

Mic Channel

Va

lue

xx xx xx

Command

Mic Channel

Va

lue

xx xx xx

Command

Mic Channel

Va

lue

SysEx End

Put 1 to 64 3-byte Commands Here

Aphex MIDI I.D.

System Exclusive (SysEx) Parametric Control String