0 metering, 0 compressor functions – Aphex Project 500 User Manual

Page 5

Advertising
background image

Page 8

Page 9

4.1 THRESHOLD

When the input signal level exceeds the thresh- old setting, the

compressor engages. Turning the knob counterclockwise lowers the

threshold so that compression begins at a lower input level. Turning

the knob clockwise raises the threshold so that compression only

happens at higher input levels. The threshold can be set from

-20dBu to +30 dBu.

4.2 SPEED

The Easyrider Compressor has a complex set of time constants that

adapt to the sound wave characteristics. The base time constant

can be set by the user with the Speed control. This can be looked

at like the release time control on other compressor/limiters. With

faster speed (shorter release time) the audio will be more aggres-

sively compressed and you will hear the sound becoming busier and

fatter. Regardless of the Speed setting, the automatic time con-

stants are working, just faster or slower.

4.3 OUTPUT KNOB

The Output level knob determines the overall output level of the

module and drives the VU meter.

4.4 COMPRESSOR ON/OFF BUTTON

This button turns the compressor function on and off. When on the

button will light up.

5.0 METERING

5.1 GR/PK SWITCH

When this switch is set to GR (Gain Reduction) the two-color

bargraph indicates both compression and gating. Compression

is shown as a green down-going bar while gating drives one red

bar downwards. When the switch is set to PK the meter becomes

an output PEAK meter. The meter will indicate output levels from

-16dBu to +21dBu.

4.0 COMPRESSOR FUNCTIONS

Advertising