Understanding the warnings & alarms – Basement Watchdog Big Dog User Manual

Page 10

Advertising
background image

Page 9

5. Hooking up the pump: Plug the

pump wires into the pump connector
on the back of the control unit.

6. Hooking up the battery: Remove

the wing nuts. Coat the terminals
with a little petroleum jelly to prevent
corrosion. Attach the battery cables
to the battery...the BLACK wire to the
POSITIVE (+) post, the WHITE wire
to the NEGATIVE (-) post. Tighten
the wing nuts.

7. Immediately plug the AC power cord

into a grounded AC wall outlet. (A
surge protector that protects all three
pins on the power line is recom-
mended.) You will have 10 seconds
before the power failure alarm will
sound. The alarm will be silenced
once the unit it plugged into the wall.
At this time the computer control unit
will perform a quick test of the battery
and pump. However, until a full test
has been completed, the reading
under the “Hours of continuous
pumping” will not be accurate.

8. To initiate the full test: Press the

white “SILENCE/TEST” button and
hold it down for approximately 20
seconds until three long “beeps” are
heard. This will activate the full test
and charge cycle. The “Battery
charging” and “Testing battery” lights
will both be lit on the front panel of
the control unit. When the test is
completed (a process that takes from
six to eight hours) the hour lights will
be correctly displayed on the control
panel.

9. Put the cover on the battery box and

secure it with the safety strap.

The Basement Watchdog A/C-D/C
Sump Pump System is ready to use!

Alarm can be

Alarm shuts off

silenced before

automatically

problem is

when problem

Warning

Light

Alarm

corrected

is corrected

Battery hooked up

improperly

Steady red

No

Not applicable

Yes

Battery fluid low

Steady red

Yes

Yes

Yes

Battery discharged

Steady red

Yes

No

Yes

Battery problem

Steady red

Yes

Yes

No, must push

white test button

Power failure

Steady red

Yes

Yes

Yes

Pump failure

Steady red

Yes

No

No, must push

white test button

Pumping

Steady red

No

Not applicable

Yes

Pumping

Flashing red

Yes

No

Yes

Pump was activated

Steady red

Yes

No*

No, must push

white test button

Battery fuse has blown

Steady red

Yes

No

Yes

5

8a

6

8b

7

*Note: During a continuing emergency the pump may be activated many times. To silence the
alarm, you may set the blue switch to “OFF” instead of “ON”. Be sure to switch it back when
the emergency is over.

Understanding the Warnings & Alarms

SURGE

PROTECTOR

Advertising