UDM 35/40 PANEL METER USER MANUAL


15



Configuring the Display Color for Alarm Event (UDM40/BD40 only)

When

is displayed, the color of the display may be set to be RED,

ORANGE, or GREEN during the alarm event. Selecting NONE results in the
basic display color being used during alarm event. Use the

keys to make

your selection and press

to confirm. Press

to advance to the next

program step sequence.

Digital Filtering


The digital panel meters are extremely fast to follow the trend of input signals and
to display the relevant values. Unlike in analog panel meters, which tend to filter
the input and present a more stable indication, the fluctuations in digital panel
meters can be quite fast and prevent the user from clearly reading the displayed
value. Fluctuations can also be introduced when the resolution of the displayed
value is higher than the input resolution. The use of a digital filter results in
higher stability of the displayed value.

There are two types of filter parameters.

The first is

and it defines the operating range of the filter. Generally,

Fil.S represents the resolution (in digits) wanted to assign to the display. It is
suggested to set this parameter to evaluate the amplitude of the fluctuation on
the display and use this value as Fil.S. If, for example, a display value fluctuates
between 2.5 and 3.4, it means that the fluctuation is 9 digits and the Fil.S must
be set as “9”.

When

is displayed, you may elect to program filter values by pressing the

key. This results in

being displayed. Using the

key, toggle to

the desired position and select the value to enter by using the

keys. Press

to confirm and advance to the next step in the sequence.