Cooper Instruments & Systems DCM 437 Current Bridge Amplifier User Manual

Page 5

Advertising
background image

CF 27

5

4/2001


Bridge Balance
The Bridge Balance pot provides up to 68% of full-scale tare weight adjustment when using a 350-ohm, 3mV/V load
cell. The DCM 437 can then be adjusted to provide full span output with only about 10% of the cell’s range.

DCM 437 Gain Switch

Bridge Output Signal for:

Gain Switch

Position “ON”:

0 to 20 mA

4 to 20 mA

1

50mV to 62.5mV

40mV to 50mV

2

25mV to 50 mV

20mV to 40mV

3

12.5mV to 25mV

10mV to 20mV

4

6.25mV to 12.5mV

5mV to 10mV

5

3.125mV to 6.25mV

2.5mV to 5mV


Mechanical Specifications

Advertising