Electrical Grounding Instructions

This appliance is fitted with an electrical junction box with 3 wires, one of which (green/yellow) serves to ground
the appliance. To protect you against electric shock the green and yellow wire must be connected to the grounding
wire in your home electrical system and it must not be cut or removed under any circumstances. Failure to do so
may result in death or injury to persons.

Facing the front of the range hood remove the left knockout and the Junction box cover and install the conduit
connector in junction box.

Run 3 wires; black, white and green, according to the National Electrical Code and local codes and ordinances in
½” conduit from service panel to junction box.

Connect black wire from service panel to black or red in junction box, white-to-white and green to green-yellow.





Check all light bulbs to make sure they are secure in their sockets.

Turn power on in service panel.


Check lights and blower operation.