099403

CLEANING

AND

MAINTENANCE

ODS/PILOT AND BURNER ORIFICE

• Use a vacuum cleaner, pressurized air, or small, soft bristled brush to clean.

CABINET

Air Passageways

• Use a vacuum cleaner or pressurized air to clean.

Exterior

• Use a soft cloth dampened with a mild soap and water mixture. Wipe the

cabinet to remove dust.

WARNING ICON

G 001

WARNING

Turn off heater and let cool before cleaning.

WARNING ICON

G 001

CAUTION

You must keep control areas, burner, and circulating air
passageways of heater clean. Inspect these areas of heater before
each use. Have heater inspected yearly by a qualified service
person. Heater may need more frequent cleaning due to excessive
lint from carpeting, bedding material, etc.

Note: All troubleshooting

items are listed in order of

operation.

TROUBLE-

SHOOTING

WARNING ICON

G 001

WARNING

Turn off heater and let cool before servicing. Only a qualified
service person should service and repair heater.

POSSIBLE
CAUSE

1. Ignitor electrode posi-

tioned wrong

2. Ignitor electrode broken
3. Ignitor electrode not con-

nected to ignitor cable

4. Ignitor cable pinched or

wet

5. Piezo ignitor nut is loose

6. Broken ignitor cable

7. Bad piezo ignitor

OBSERVED
PROBLEM

When ignitor button
is pressed, there is no
spark at ODS/pilot

REMEDY

1. Replace ignitor

2. Replace ignitor
3. Reconnect ignitor cable

4. Free ignitor cable if

pinched by any metal or
tubing. Keep ignitor cable
dry

5. Tighten nut holding piezo

ignitor to heater cabinet.
Nut is located inside
heater cabinet at top

6. Replace ignitor cable

7. Replace piezo ignitor

WARNING ICON

G 001

CAUTION

Never use a wire, needle, or similar object to clean ODS/pilot. This
can damage ODS/pilot unit.

Advertising