099403

OBSERVED
PROBLEM

Burner does not light
after ODS/pilot is lit

Delayed ignition of
burner

Burner backfiring dur-
ing combustion

Yellow flame during
burner combustion

Slight smoke or odor
during initial opera-
tion

Heater produces a
whistling noise when
burner is lit

REMEDY

1. Clean burner orifice (see

Cleaning and Mainte-
nance
, page 20) or replace
burner orifice

2. Replace burner orifice

3. Contact local propane gas

company

1. Contact local propane gas

company

2. Clean burner orifice (see

Cleaning and Mainte-
nance
, page 20) or replace
burner orifice

1. Clean burner orifice (see

Cleaning and Mainte-
nance
, page 20) or replace
burner orifice

2. Replace burner
3. Replace gas regulator

1. Check burner for dirt and

debris. If found, clean
burner (see Cleaning and
Maintenance
, page 20)

2. Replace gas regulator

1. Problem will stop after a

few hours of operation

1. Turn control knob to

LOW position and let
warm up for a minute

2. Operate burner until air is

removed from line. Have
gas checked by local pro-
pane gas company

3. Observe minimum instal-

lation clearances (see
Figure 4, page 10)

4. Clean burner (see Clean-

ing and Maintenance,
page 20) or replace
burner orifice

POSSIBLE
CAUSE

1. Burner orifice is

clogged

2. Burner orifice diameter

is too small

3. Inlet gas pressure is

too low

1. Manifold pressure is

too low

2. Burner orifice is

clogged

1. Burner orifice is

clogged or damaged

2. Burner damaged
3. Gas regulator defective

1. Not enough air

2. Gas regulator defective

1. Residues from manu-

facturing processes

1. Turning control knob

to HIGH position
when burner is cold

2. Air in gas line

3. Air passageways on

heater blocked

4. Dirty or partially

clogged burner orifice

TROUBLE-

SHOOTING

Continued