Wilkerson lubricators and filters, Warning – Humboldt HM-4165 3-Cell Manual Control Panel User Manual

Page 13

Advertising
background image

9

Introduction

Follow these instructions when installing, operating, or servicing the product.

Application Limits

These products are intended for use in general purpose compressed air

systems only.

Operating Inlet Pressure:

kPa

PSIG

bar

with Polycarbonate Bowl

1000

150

10.3

with Metal Bowl

1700

250

17.0

NOTE: The maximum recommended pressure drop for a particulate filter is

70 kPa (10 psig, 0.7 bar)

Ambient Temperature Range:

with Polycarbonate Bowl

0°C to 52°C (32°F to 125°F)

with Metal Bowl

0°C to 80°C (32°F to 175°F)

ANSI Symbols

Micro-Mist Lubricators (Figure 1)

Description

These micro-mist lubricators are designed to deliver an atomized oil mist to air

operated tools, motors, and other pneumatic equipment. Units are equipped

with full-view sight glass for visual indication of oil drop rate, needle valve feed

adjustment to regulate oil drop rate, and a venturi bypass disc to compensate

for changes in air flow demands.

Installation of Lubricator

1.

Lubricator should be installed with reasonable accessibility for service

whenever possible - repair service kits are available. Keep pipe and tubing

lengths to a minimum with inside clean and free of dirt and chips. Pipe

joint compounds should be used sparingly and applied only to the male

pipe – never into the female port. Do not use PTFE tape to seal pipe joints

- pieces have a tendency to break off and lodge inside the unit, possibly

causing malfunction.

2.

Install lubricator so that air flow is in the direction of arrow on body.

3.

Installation should be upstream from, and as close as possible, to the

device it is to lubricate (valve, cylinder, tool, etc.). Whenever possible,

avoid locations that require air-borne oil to move in an upward direction to

reach the device to be lubricated.

4.

The installation of an individual lubricator for each air consuming device

provides best assurances of proper lubrication.

5.

In new installations, it is good practice to “wet down” the inside diameter of

piping and/hose with oil before making final connections. Although your

lubricator delivers oil to the line, pre-coating the inside diameter with oil

helps insure that proper amounts of oil are delivered to the point

of application.

Operation & Service of Lubricator

!

Warning: Before filling, inlet pressure must be eliminated and

then de-pressurize system pressure.

1.

FILLING - After de-pressurizing system, remove fill plug or bowl to refill

lubricator. Fill bowl to fill line indicated on the bowl with oil of 150 to 200

SSU at 100°F viscosity - same as SAE No. 10 (petroleum based hydraulic

oils or spindle oils are good examples). DO NOT USE OILS WITH TACKY

ADDITIVES, COMPOUND OILS CONTAINING SOLVENTS, GRAPHITE,

SOAPS OR DETERGENTS. (Automotive oils generally contain detergents

and are not recommended.

2.

Replace the fill plug or bowl and seat firmly. Excessive torque is not

necessary. The lubricator is now ready for setting.

3.

OIL DELIVERY ADJUSTMENT - To adjust oil delivery, turn the adjusting

needle on top of the lubricator.

Leaner - Clockwise

Richer - Counterclockwise

By counting the number of drops per minute in the sight dome, you can adjust

lubricator to your required setting. Approximately 3% of the droplets visible in

the sight dome go downstream; adjust drip rate accordingly. Consult oil delivery

conversion chart (see below).
Generally, one drop per minute downstream for every 10-15 SCFM flow is

satisfactory. 25 drops per minute equals one ounce per hour - volume of oil

passing through the sight dome.
NOTE: This is a constant density type lubricator which delivers a constant

ratio of oil to air flow. Therefore, if air flow increases or decreases, oil

delivery will be effected proportionately. ONLY IF DIFFERENT RATIO

IS DESIRED NEED YOUR NEEDLE VALVE SETTING BE CHANGED

AFTER YOUR INITIAL SETTING.

1

2

3

4

5

6

7

Downstream Delivery DPM

33

67

100

133

167

200

233

Dome Drip Rate DPM

Oil Delivery Conversion

3% of Drip Rate to Downstream

Installation & Service Instructions:

1M103G
Miniature Series

Micro-Mist Lubricators &

Particulate Filters
ISSUED: November, 2003

Supersedes: September, 2000

Doc.# 1M103, ECN# 030539, Rev. 8

WARNING

To avoid unpredictable system behavior that can cause personal injury

and property damage:

• Disconnect electrical supply (when necessary) before installation,

servicing, or conversion.

• Disconnect air supply and depressurize all air lines connected to

this product before installation, servicing, or conversion.

• Operate within the manufacturer’s specified pressure, temperature,

and other conditions listed in these instructions.

• Medium must be moisture-free if ambient temperature is below

freezing.

• Service according to procedures listed in these instructions.
• Installation, service, and conversion of these products must be

performed by knowledgeable personnel who understand how

pneumatic products are to be applied.

• After installation, servicing, or conversion, air and electrical

supplies (when necessary) should be connected and the product

tested for proper function and leakage. If audible leakage is present,

or the product does not operate properly, do not put into use.

• Warnings and specifications on the product should not be covered

by paint, etc. If masking is not possible, contact your local

representative for replacement labels.

WARNING

FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE

PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR RELATED

ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY

DAMAGE.
This document and other information from The Company, its subsidiaries

and authorized distributors provide product and/or system options for

further investigation by users having technical expertise. It is important

that you analyze all aspects of your application, including consequences

of any failure and review the information concerning the product or

systems in the current product catalog. Due to the variety of operating

conditions and applications for these products or systems, the user,

through its own analysis and testing, is solely responsible for making

the final selection of the products and systems and assuring that all

performance, safety and warning requirements of the application are

met.
The products described herein, including without limitation, product

features, specifications, designs, availability and pricing, are subject to

change by The Company and its subsidiaries at any time without notice.

EXTRA COPIES OF THESE INSTRUCTIONS ARE AVAILABLE FOR

INCLUSION IN EQUIPMENT / MAINTENANCE MANUALS THAT UTILIZE

THESE PRODUCTS. CONTACT YOUR LOCAL REPRESENTATIVE.

Pneumatic Division
Richland, Michigan 49083
269-629-5000

!

!

Lubricator