Dynalco AF-900PC Air/Fuel Ratio Controller User Manual

Page 102

Advertising
background image

101

/*$PAGE*/
; *************** LOG PARAMETER #12 ***************

; LOG NAME ****************************************
; User-defined alphanumeric name up to 20 characters
; in length.
;
; <BLANK> (default)
138.12=

; LOG ENABLE **************************************
; 0 DISABLED (default)
; 1 ENABLED
135.12=0

; LOG GRAPH NUMBER ********************************
; Select specific graph number to plot data in
; Excel chart. When the same graph number is
; set for multiple log parameters, then these
; log parameter values will be plotted on the
; same Excel chart.
;
; Min Val Max Val
; 0 (default) -> 255 (in graph #)
139.12=0

; LOG PARAMETER NUMBER ****************************
; Set Parameter Number to log.
;
; Min Val Max Val
; 0 (default) -> 65535 (in parameter #)
136.12=0

; LOG PARAMETER INDEX *****************************
; Set Parameter Index to log.
; Indices used for multiple channel parameters.
; If parameter is NOT a channel parameter, set
; index value to 255.
;
; Min Val Max Val
; 0 (default) -> 255 (in parameter index #)
137.12=0




;

Advertising