Resetting to factory defaults – EcoPure MW_MW30_7339971A User Manual

Page 27

Advertising
background image

27

Miracle Water Installation & Operation Manual

NOTE: Be sure water is in contact with the salt, and not separated by a salt bridge...

see page 23.

5. While in this diagnostic screen, the following information is available and may be beneficial for

various reasons. This information is retained by the computer from the first time electrical power

is applied to the face plate.
a. Press UP p to display the number of days this face plate has had electrical power applied.
b. Press DOWN q to display the number of regenerations initiated by this face plate since the

LE code number was entered.

6. Press and hold the (Select/Menu) button until LE31 shows in the display.

SELECT

MENU

This code identifies the softener model. If the wrong number shows, the softener will operate

on incorrect programming.

7. Return the present time display — Press the (Select/Menu) button.
8. To change LE number — Press the UP p or DOWN q button until the correct code shows.

Then, press the (Select/Menu) button to return to the present time display.

SELECT

MENU

SELECT

MENU

To reset the electronic controller to its factory default for all settings (time, hardness, etc.):
1. Press the (Select/Menu) button and hold it until the display changes twice to show

“CODE” and the flashing model code.

2. Press the UP p button (a few times, if necessary) to display a flashing “SoS”.

3. Press the (Select/Menu) button, and the electronic controller will restart.
4. Set the present time, hardness, etc., as described on pages 17 & 18.

Resetting to Factory Defaults

SELECT

MENU

SELECT

MENU

Advertising