Step 11. connect transformer, Step 13. start a recharge, Step 14. restart the water heater – EcoPure MW_MW30_7301415D User Manual

Page 16

Advertising
background image

16

Miracle Water Installation & Operation Manual

Step 11. Connect Transformer

NOTE: Check to be sure all leadwire connectors are secure on the back of the electronic

board.

CAUTION: Be sure all wiring is away from the valve gear and motor area, which rotates dur-

ing regenerations.

1. Plug the transformer into a continuously “live”, grounded house electrical outlet, approved by

local codes. THE UNIT WORKS ON 24V ONLY. DO NOT CONNECT WITHOUT THE TRANS-
FORMER.

Step 12. Install the Salt Hole and Faceplate Cover(s)

Complete the Programming Steps on Pages 18, 19 and 20.

Step 13. Start a Recharge

Press the (RECHARGE) button and hold for three seconds until Recharge Now begins
to flash in the timer display, starting a recharge. This recharge draws the sanitizing bleach into and
through the unit. Any air remaining in the unit is purged to the drain.

Step 14. Restart the Water Heater

Turn on the electricity or fuel supply to the water heater, and light the pilot, if applicable.

NOTE:

The water heater is filled with HARD water and, as hot water is used, it refills with
conditioned water. In a few days, the hot water will be fully conditioned. To have
fully conditioned hot water immediately, wait until the recharge (Step 13) is over.
Then, drain the water heater until water runs cold.

Advertising