MW-40 DEMAND TIMER FEATURE, SETTINGS, AND SERVICE, continued


service: TIMER / SOFTENER, SERVICE CHECKOUT PROCEDURE ..........................................

If you are not getting soft water, and an error code is
not displayed, use the procedures below to find the
problem. First, make the following visual checks.

VISUAL CHECKS: (1) Is there electrical power to the
outlet the softener transformer is plugged into? (2) Is

there salt in the storage tank? (3) Is the plumbing
bypass valve(s) directing water for soft water service...
see pages 6 and 8? (4) Is the valve drain hose open
to the drain, not elevated too high, and unobstructed?
If you do not find a problem with the visual checks,
continue below.


service: MANUAL INITIATED ELECTRONICS DIAGNOSTIC.......................................................

1. To enter diagnostics, press
and hold the DATA button until
the display appears as shown
here. The dY and number, in the
top part of the display, is days
since the last recharge. See (A)
and (B) following, explaining the
bottom portion of the display.

NOTE: If the softener is in the
middle of a regeneration, the top
part of the display shows the
cycle

of

regeneration,

and

minutes of the cycle remaining. If
2 cycle names are flashing, the
valve is in transition between the
cycles.

(A) The 3 digits, under WATER
MANAGEMENT

SYSTEM,

indicate water meter operation as follows:

!

000 (steady) = soft water not in use…no flow through

the meter.

— OPEN A NEARBY SOFT WATER FAUCET —

!

000 to 140 (continual) = repeats display for each

gallon of water passing through the meter.

If you don’t get a reading in the display, with faucet
open, pull the sensor from the valve outlet port. Pass a
small magnet back and forth in front of the sensor.
You should get a reading in the display. If you get a
reading, unhook the in and out plumbing and check
the turbine for binding.

NO SOFT WATER

TIMER SHOWS WRONG TIME

AND DAY, AND/OR IS FLASHING

Electrical power was off. Re

set the correct time of day..

Investigate reason for power

loss. Besure outlet for softener

cannot be switched off.

TIMER DISPLAY BLANK

Check electrical power to tim

er (outlet, transformer, power

cable, all connections.

NO POWER

POWER OKAY

REPAIR AS

NEEDED

TIMER

DEFECTIVE

TIMER DISPLAY SHOWS CORRECT

TIME AND DAY, AND IS STEADY

Do manual

diagnostics

Do manual diag

nostics to verify

proper function.