Automatic water softener – EcoPure MW_MW40_450216 User Manual

Page 24

Advertising
background image

..................................................AUTOMATIC WATER SOFTENER

MW-40 DEMAND TIMER FEATURE, SETTINGS, AND SERVICE, continued

(B) This display segment (

), in the following

table, indicates an open POSITION switch. The other
indicates a closed switch. Use the RECHARGE button
to manually advance the valve into each cycle and
check correct switch operation.

CORRECT SWITCH

DISPLAYS

VALVE CYCLE STATUS

Valve in service, fill,
brining, backwash or fast
rinse position.

Valve rotating from one
position to another.

2. Press the DATA button again.
This diagnostic display, shows the
total number of recharges (top)
since the timer was connected to
electrical power.

The number of days since the
timer was connected to electrical power, is shown in
the bottom part of the display. If over 1999 days, a (x
10) indicator shows, meaning you must multiply the
number shown times 10.

3. Press DATA once again to return the present time
to the display.

service: MANUAL ADVANCE REGENERATION CHECK .............................................................

This check verifies proper operation of the valve
motor, brine tank fill, brine draw, regeneration flow
rates, and other timer - valve functions. First, make
the initial checks, and the manual initiated
diagnostics.

NOTE: The face plate display must show a steady
time (not flashing).

1. Press the RECHARGE button and hold in for 3
seconds. RECHARGE NOW begins to flash as the
softener enters the fill cycle of regeneration. Remove
the brinewell cover and, using a flashlight, observe fill
water entering the brine tank.

!

If water does not enter the tank, look for an

obstructed nozzle, venturi, fill flow plug, brine tubing,
or brine valve riser pipe.

2. After observing fill, press the RECHARGE button to
move the softener into brining. A slow flow of water to
the drain will begin. Verify brine draw from the brine
tank by shining a flashlight into the brinewell and
observing a noticeable drop in the liquid level.

NOTE: Be sure a salt bridge is not preventing water
with salt contact.
!

If the softener does not draw brine…

…Nozzle and/or venturi dirty or defective.
…Nozzle and venturi not seated properly on gasket.
…Restricted drain (check drain fitting and hose).
…Defective nozzle and venturi seal.

…Other inner valve defect (rotor seal, rotor & disc,
wave washer, etc.).

3. Press RECHARGE to move the softener into fast
rinse. Again look for a fast drain flow. Allow the
softener to rinse for a few minutes to flush out any

brine that may remain in the resin tank from the brining
cycle test.

4. To return the softener to service, press RECHARGE.

24