TABLE 10: D1EB060 SUPERHEAT CHARGING (IMPERIAL)

OUTDOOR

TEMPERATURE

(°F)

SUPERHEAT AT COMPRESSOR SUCTION (°F)

AIRFLOW = 2,000 CFM

INDOOR WB TEMPERATURE (°F)

55

57

59

61

63

65

67

69

71

73

75

65

21.9

23.8

25.7 27.6 29.4 31.3 33.2 34.2 35.1 35.6 36.1

70

16.0

18.4

20.7 23.0 25.3 27.6 30.0 31.3 32.7 33.4 34.0

75

10.1

12.9

15.7 18.4 21.2 23.9 26.7 28.5 30.2 31.1 32.0

80

-

7.5 10.7 13.9 17.1 20.3 23.5 25.6 27.8 28.9 29.9

85

-

-

5.6 9.3 12.9 16.6 20.2 22.8 25.3 26.6 27.9

90

-

-

-

7.6 10.6 13.6 16.7 19.8 22.9 24.4 26.0

95

-

-

-

5.9 8.3 10.7 13.1 16.7 20.4 22.2 24.0

100

-

-

-

-

6.4 8.2 10.1 13.2 16.3 17.9 19.5

105

-

-

-

-

-

5.8 7.0 9.6 12.3

13.6

14.9

110

-

-

-

-

-

-

-

6.1 8.2 9.3 10.4

115

-

-

-

-

-

-

-

-

-

-

5.8

TABLE 11: D1EB060 SUPERHEAT CHARGING (METRIC)

OUTDOOR

TEMPERATURE

(°C)

SUPERHEAT AT COMPRESSOR SUCTION (°C)

AIRFLOW = 0.94 M

3

/S

INDOOR WB TEMPERATURE (°C)

13

14

15

16

17

18

19

21

22

23

24

18

12.2

13.2

14.3

15.3

16.4 17.4 18.4 19.0 19.5 19.8 20.0

21

8.9

10.2

11.5

12.8

14.1 15.4 16.6 17.4 18.2 18.5 18.9

24

5.6

7.2 8.7

10.2

11.8 13.3 14.8 15.8 16.8 17.3 17.8

27

-

4.1 5.9 7.7 9.5 11.3 13.0 14.2 15.4 16.0 16.6

29

-

-

3.1 5.2 7.2 9.2 11.2 12.6 14.1 14.8 15.5

32

-

-

-

4.2 5.9 7.6 9.3 11.0 12.7 13.6 14.4

35

-

-

-

3.3

4.6 5.9 7.3 9.3 11.3

12.3

13.3

38

-

-

-

-

3.6 4.6 5.6 7.3 9.1 9.9 10.8

41

-

-

-

-

-

3.2 3.9 5.4 6.8 7.6 8.3

43

-

-

-

-

-

-

-

3.4 4.6 5.2 5.8

46

-

-

-

-

-

-

-

-

-

-

3.2

Advertising