Propane forced air heaters, Page 2 – HeatStream HS-150V-GFA User Manual

Page 2

Advertising
background image

Unpacking

1. Remove all packing items applied to heater for shipment. Keep

plastic cover caps attached to inlet connector and hose/regula-
tor assembly for storage.

2. Remove all items from carton.

3. Check all items for shipping damage. If heater is damaged,

promptly inform dealer where you purchased the heater.

The Propane (LP) gas pressure regulator
and hose assembly supplied with the

heater must be used without alteration.

Product Features

- Portable, stable and fully assembled.

- Wind resistant and rain protected.

- Continuous spark ignition or piezo spark ignition.

- 100% safety shut-off system.

- Adjustable input ratings (Except HS-40-GFA).

- Adjustable Height Controller.

PROPANE INFORMATION

The Propane (LP) cylinder must also be
equipped with the following:

- A collar to protect the gas valve.

- A shut-off valve terminating a LP cylinder

valve outlet as specified in the American
National Standard for Compressed Gas
Cylinder Valve Outlets and Inlet Connections.

- A safety relief valve having direct communica-

tions with the vapor space of the LP cylinder.

- An arrangement of vapor withdrawal.

Propane

Forced Air Heaters

NEVER LEAVE HEATER UNATTENDED

WHILE BURNING, CONNECTED TO A

POWER SOURCE, OR WHILE

CONNECTED TO A FUEL SOURCE

Page 2

Pinnacle Products International, Inc. Propane Forced Air User’s Manual

Specifications

Model #

Rating

BTU/Hr

Fuel

Consumption

Electrical

Input

Manifold

Pressure

Amps

Weight

(Lbs)

Size

(L x W x H)

HS-40-GFA

40,000

1.9 Lbs/Hr

120V, 60 Hz

11” W.C.

0.6

15.2

18.1” x 7.7” x 12.8”

HS-50V-GFA

30,000 -

50,000

1.4 to 2.3 Lbs/Hr

120V, 60 Hz

10.5” W.C.

0.6

15.2

18.1” x 7.7” x 12.8”

HS-100V-GFA

70,000 -

100,000

3.3 to 4.6 Lbs/Hr

120V, 60 Hz

10” W.C.

0.8

22.7

25.12” x 9” x 15.5”

HS-150V-GFA

120,000-

150,000

5.6 to 7.0 Lbs/Hr

120V, 60 Hz

8” W.C.

0.8

22.7

25.12” x 9” x 15.5”

CAUTION

Guard

Gas Valve Knob

Base

Inlet Shell

Height Controller

Outer Shell

Figure 1. Product Features

Table 1:

Specifications

Specifications subject to change without notice

If the information in this manual is not
followed exactly, a fire or explosion may

result causing property damage, personal injury or loss of
life.

- Do not store or use gasoline or other flammable vapors

and liquids in the vicinity of this or any other appliance.

- An LP cylinder not connected for use shall not be stored

in the vicinity of this or any other appliance.

- WHAT TO DO IF THE SMELL OF GAS IS PRESENT:

- DO NOT attempt to light heater
- Extinguish any open flame
- Shut off gas to heater
- If odor continues, contact your local gas supplier or

fire department.

- Do not touch any electric switch, do not use any

phone in your building

- Immediately call your gas supplier from a neighbors

phone. Follow the gas suppliers instructions

- If you can not reach your gas supplier, call the fire

department

- Service must be done by a qualified service agency

or the gas supplier.

DANGER

The state of California requires the following
warning:

Combustion by-products produced when using this product contain car-
bon monoxide, a chemical known to the state of California to cause can-
cer and birth defects (or other reproductive harm).

WARNING

This is an unvented portable heater. It
uses air (oxygen) from the area which it is

used. Ample combustion and ventilation air must be provid-
ed. See VENTILATION on page 5.