Warning, Replacement parts technical service specifications – Coleman 5080A751 User Manual

Page 10

Advertising
background image

10

WARNING

Use only original replacement parts. Do not substitute or use generic parts.
Improper replacement parts could cause serious or fatal injuries.

REPLACEMENT

PARTS

TECHNICAL

SERVICE

SPECIFICATIONS

5085A751

5080A751

• Rating (BTU/Hr)

80,000 to 200,000

30,000 to 80,000

• Fuel

Propane Vapor Only

Propane Vapor Only

• Fuel Consumption

Gallons/Hour

0.9 minimum/2.2 maximum

0.3 minimum/0.9 maximum

Pounds/Hour

3.8 minimum/9.3 maximum

1.4 minimum/3.8 maximum

• Supply Pressure (To Regulator)

Maximum

Tank Pressure

Tank Pressure

Minimum, for input adjustment

24 psi

24 psi

• Regulator Outlet Pressure

10 psi

10 psi

• Weight (Pounds)

14.7

12.24

• Size (Inches)

28

3

/

4

x 13

1

/

4

diameter

21 x 13

1

/

4

diameter

• Minimum Ambient

Temperature for use

0

°

F

0

°

F

• Shipping Dimensions (Inches)

29

1

/

2

x 14

1

/

8 X

14

1

/

8

21

3

/

4

x 14

1

/

8 X

14

1

/

8

• Shipping Weight (Pounds)

17

14.1

If you have questions, contact Coleman at 1-800-835-3278 or TDD: 316-832-8707.

I.D.

PART NO.

DESCRIPTION

NO.

1

5080-3111

Electronic Ignition Assembly

2

5080-1491

Knob and Screw

3

5080-5651

Hose and Regulator Assembly

4

5080-2181

Gas Tip (for 5080A Heater)

5085-2181

Gas Tip (for 5085A Heater)

5

5080-3271

Thermocouple and Clip

6

5080-1151

Top Cap and Screws

7

5410A1381

O-ring

1

2

3

4

5

6

7

Advertising