Campbell Hausfeld Oil-Lubricated Compressor HL5403 User Manual

Page 7

Advertising
background image

7

hL5403, hL5404

troubleshooting Chart (Continued)

symptom

Possible Cause(s)

Corrective action

Motor hums but cannot

run or runs slowly

1. Circuit overloaded

1. Disconnect other electrical appliances from circuit or

operate compressor on its own branch circuit

2. Low voltage

2. Check voltage at wall outlet with voltmeter.

3. Extension cord usage - wrong gauge

wire and/or too long.

3. Remove extension cord or refer to Extension Cord

Chart on page 4

4. Loose electrical connections

4. Check all electrical connections

5. Worn check valve

5. Replace check valve

Do not disassemble check valve

with air in tank; bleed tank

6. Defective unloader valve (on

pressure switch)

6. Replace unloader valve

7. Defective motor capacitor(s)

7. Replace capacitor(s)

8. Defective motor

8. Replace motor

Motor reset protector

cuts out repeatedly

1 Lack of proper ventilation / room

temperature too high

1. Move compressor to well ventilated area

2. Clogged intake filter

2. Clean or replace filter

3. Circuit overloaded

3. Check for proper fuse, use time-delay fuse.

Disconnect other electrical appliances from circuit or

operate compressor on its own branch circuit

4. Extension cord usage - wrong gauge

wire and/or too long.

4. Remove extension cord or refer to Extension Cord

Chart on page 4

5. Worn check valve

5. Replace check valve

Do not disassemble check valve

with air in tank; bleed tank

6. Defective unloader valve (on

pressure switch)

6. Replace unloader valve.

7. Defective motor

7. Replace motor

Knocks, rattles, and/or
excessive vibration

1. Loose mounting bolts

1. Tighten bolts.

2. Tank not level

2. Use sturdy wedge/object to bring tank to level

position.

3. Cylinder or piston is worn/scored

3. Replace or repair as necessary.

Compressor runs
continuously and safety
valve opens as pressure
rises

1. Defective pressure switch

1. Replace switch.

2. Defective safety valve

2. Replace safety valve with genuine replacement part.

Air leaking from
unloader valve on
pressure switch

1. Check valve stuck in an open

position

1. Replace check valve.

2. Unloader valve stuck in open

position

2. Replace unloader valve.

Do not disassemble check valve

with air in tank; bleed tank

Advertising
This manual is related to the following products: